High and low volume air sampling
equipment for Emergency Response-Nuclear-Medical-Laboratories
By RADECO
Check out the full kit you can order!
Click on the link and download the PDF File for the KIT
Each Kit includes the following:
 | Air Sampler (Choose from the Sampler List) |
 | Open Face Combo Filter Holder |
 | C812 Air Flow Calibrator |
 | 2500-80 Calibrator Adapter |
 | RAD12/24 VDC-Battery Pack-If Required |
 | CP100 Radioiodine Cartridge |
 | 2" LB5211 Filter Paper |
AIR SAMPLER MODELS
 | H-809 |
 | H-809C |
 | H-810 |
 | H-810DC |
|
MODEL H-809CTM-
PORTABLE 12/24 VDC AIR SAMPLER |
|
 |
The Model
H-809C is a lightweight GRAB sampler designed for sampling
airborne particulates or combination particulates and iodines in
the field using a motorized vehicle. The unit is supplied with a
battery jumper type cable with large alligator clamps for
connecting directly to battery terminals. It may be used with one
of the RADeCO precision machined aluminum sample holders, selected
filter discs, high quality radioiodine cartridges, and may be
calibrated using one of the RADeCO NIST traceable air flow
calibrators to give the user a fully qualified air sampling
system.
The flow
rate capability of the H-809C is dependent upon the pressure drop
across the filter media used. Five CFM may be obtained through a
4" diameter filter, while two to three CFM is the upper limit for
open face combination filter and charcoal cartridge filter media.
High pressure drop filters and cartridges are not recommended for
use with this unit. A number of different sample holders are
available as accessories.
|
More Information
|
MODEL H-809VTM -
PORTABLE HIGH VOLUME AIR SAMPLER |
|
 |
The RADeCO Model H-809V is a
lightweight, ruggedized grab sampler designed specifically for
heavy duty industrial applications for sampling airborne
particulates or combination particulates and iodines. The Model
H-809V may be used with RADeCO sample holders that house selected
filter discs and high quality RADeCO radioiodine cartridges. The
unit may be calibrated using one of the RADeCO NIST traceable air
flow calibrators to give the user a fully qualified air sampling
system.
There are two versions of the 120V and 230V AC H-809 series air
samplers. The H-809VI (pictured) has a small, sintered metal
exhaust diffuser and is normally used with combination filter and
cartridge holders (typical flow range from 1-8 cfm). The H-809VII
has a large exhaust diffuser and is normally used with 4" diameter
filter holders (typical flow range from 1-30 cfm).
Standard features of the H-809 series include a spring-loaded face
guard, which protects the switch, fuse and flow adjust knob; top
mounted eye bolt and carrying strap; and a plastic-coated metal
cord clamp that prevents internal damage caused by excess tension
on the power cord. The industry standard for high volume air
sampling.
|
More Information
|
MODEL H-810TM - HIGH
VOLUME AIR SAMPLER WITH AIR VOLUME TOTALIZER |
|
 |
The Model
H-810 is a dependable, lightweight RADeCO Grab sampler which
incorporates the reliability of the Model H-809V with an Air
Volume Totalizer, the new way to measure the volume of air
sampled. This microprocessor based unit is designed to eliminate
the use of rotameters and mechanical time meters, simplifying air
sampling procedures while adding significantly higher accuracy to
air sampling data. The Air Volume Totalizer portion of the sampler
is composed of an enclosed air-turbine which rotates at speeds
proportional to the air velocity of the sampled air. The turbine's
rotation is sensed by a reflective sensor/breaker disk. The
microprocessor converts the signal to volume and displays the FLOW
RATE, TOTAL VOLUME and ELAPSED TIME on the LCD readout.
The Model
H-810 may be operated in the TOTAL VOLUME mode or the TOTAL
ELAPSED TIME mode with the mode of operation predetermined by the
user's established procedures. All functions are entered during
the calibration mode. The functions/parameters that are
established during calibration may be locked in using the keypad
security. When the keypad security is on, all keys on the keypad
are disabled, with the exception of the START/STOP and UNITS keys.
The UNITS key will toggle the LCD display from CFM to LPM.
|
More Information
|
Air Sampling Filter Holders |
|

 |
RADeCO has available the finest
line of precision machined, all aluminum, holders for air sampling
media. There are four different types of holders:
(1. )
Open Face Filter Holder, (2.)
Inline Filter Holder, (3.)
Open Face Combination Filter and Cartridge Holder, and (4.)
Inline Combination Filter and Cartridge Holder. All four types are
available for the RADeCO 809, 810,series of air samplers.
RADeCO
pioneered the unique two 0-ring method of preventing the sampling
air from bypassing the cartridge in the combination holder. This
method of sealing the cartridge in the lower body eliminated
gasket creep and wrinkling which caused leakage past the
cartridge. All 47 mm, 2 inch and 4 inch holders are hard anodized
to give the sample holders good chemical resistance to prevent
oxidation and to color code the various parts. The main body of
each holder is colored blue, while the filter retainer nuts and
the cartridge retainers are colored gold for 47 mm, black for 2
inch, and blue for 4 inch.
When
ordering, please specify the type of holder desired, the diameter
of the filter to be used, and in the case of a combination holder,
the type of charcoal or silver zeolite cartridge (RADeCO or Scoff)
to be used in the holder.
|
More Information
|
The RADeCO Model GY-130 |
|
 |
The
Radioiodine Sampler is a special cartridge specifically designed
for the sampling of airborne concentrations of radioiodine and
other gaseous iodine compounds in the presence of radioactive
noble gases. Testing indicates that a minimum of radioactive
Xenon, Krypton, and other noble gases are retained by the Silver
Zeolite thereby minimizing their interference with the radioiodine
measurement.
Each batch of Silver Zeolite is thoroughly tested prior to
cartridge manufacture assuring a high percentage of radioiodine
capture. A certificate is supplied with each order of cartridges
certifying the percent retention of radioiodines versus airflow
rate through the cartridge.
Routinely, these cartridges are used in-line and downstream of a
high efficiency filter which will remove radioactive particulates
which can interfere with the radioiodine measurement. Filter
papers and combination pre-filter and cartridge sample holders are
available as RADeCO accessories.
CAUTION: The Model GY-130
Radioiodine Sampler must not be used in personal respirators for
breathing protection
|
More Information
|
FILTER PAPERS |
HD-2061 This filter
paper combines good aerosol filtration efficiency with slightly
higher porosity than HD-2024. It is suggested for use as a
pre-filter of high volume filter for aerosol filtration. It is
composed of micrograms borosilicate fiber resin binder.
LB-5211
Laminated glass filter paper. These products are
high efficiency multi-purpose filter materials with good heat
resistance. They are particularly recommended for both gas and
liquid filtration in the medical field and for air monitoring
applications. The base material consists of micrograms
borosilicate fibers with low amounts of acrylic resin, the
composition of which corresponds to the description listed in DFR
Title 21, Part 177.2260, Filter, Resin Bonded.
|
|
|
Air Flow Calibrator |
|
 |
 |
Rugged Construction |
 |
Direct Reading in CFM or LPM |
 |
Reflective ARC for Parallax Correction |
 |
Better than 5% Accuracy of Reading |
 |
Three Flow Ranges |
 |
Certified and Traceable to NIST
RADeCO's Air Flow Calibrators are the most durable and
repeatable
calibration devices available. RADeCO Calibrators are
constructed of a
precision machined aluminum venturi tub and an appropriately
ranged
magnahelic gauge moutned in a rugged steel case. Our Air Flow
Calibrators are simple, cost-effective and consistently
accurate, year after
year. |
More Information
12/24 Battery Pack -
EXCELLENT TOOL FOR EMERGENCY RESPONSE OR ROUTINE SAMPLING
|

 |
| | | | | | | | | | | | |
LAURUS Systems, Inc.
Phone: 410-465-5558
8779 Autumn Hill Drive
Fax:
410-465-5257
Ellicott City, MD 21043
email: LauraLynch@LaurusSystems.com
Copyright (c) 2001 LAURUS Systems, Inc.
FastCounter by bCentral
alarming dosimeter, dosimeter, dosimeters,
Electronic dosimeter, electronic alarming dosimeter, keV, meV, Chirper,
EPD, Dose, dose rate, Beta, Gamma, X-ray, Survey Meter, RAD-60, Emergency,
Emergency Management, HAZMAT, RADOS, Electronic Dosimetry, Dosimeter,
Electronic, Alarming, Radiation Detector, Emergency response, first
responder, transportation, dosimeter, dosimeter, Radiation Detection,
Contamination Monitor, DIS, DIS-100, PDU-1, Direct Ion Chamber, Ion,
Neutron, Access Control, Waste Management, Decommissioning, Software,
Reader, Readers, Dose Control, Dose of Record, RWP, TLD, Thermoluminescent
Dosimetry, AAM, Area Monitoring, Neutron, Gamma, Beta Radiation, Alpha
Radiation, Personnel Monitoring, Air Monitor, Nuclear Power Plant,
Personnel Dose, Body Monitor, nuclear Medicine, nuclear, medical physics,
health physics, dose tracking ADR, ELD, RAD, RADSAFE, transdose,
telemetry, remote monitor, remote monitoring, Government purchase card,
credit cards, Rad-51, Rad-50, Rad-52, ADR-1, Programmable Dosimeter,
Siemens, MG, SAIC, Bicron, Indus, Survey system, IVTS, Site-Wise, MJW
Software, VSDS, ACS, Access Control Systems, Visual Survey Mapping, GEDDS,
Electronic Remote Monitoring Software, Military DIS, Military, Radiation
Protection, Radiation Detector, Public Health, Homeland Security,
Personnel Security, Customs, Custom Agent, Siemens, RADOS, MGP, SAIC,
Radiation, Dosimeter, Alarming Dosimeter, Silicon Diode Detector, Pulse,
Cyclotron, Reactor, ALARA, 10-CFR, Meets NRC Standard, NRC, NREP, CRCPD,
Electronic Dosimeter, Electronic Alarming Dosimeter, Alarm settings,
RAD-51, RAD-60, x-ray, Gamma, BETA, Neutron, Critical incident, emergency,
Online shopping, Order Dosimeters Online
|