High and low volume air sampling equipment for Emergency Response-Nuclear-Medical-Laboratories

By RADECO

Check out the full kit you can order! Click on the link and download the PDF File for the KIT

Each Kit includes the following:

bulletAir Sampler (Choose from the Sampler List)
bulletOpen Face Combo Filter Holder
bulletC812 Air Flow Calibrator
bullet2500-80 Calibrator Adapter
bulletRAD12/24 VDC-Battery Pack-If Required
bulletCP100 Radioiodine Cartridge
bullet2" LB5211 Filter Paper

AIR SAMPLER MODELS

bulletH-809
bulletH-809C
bulletH-810
bulletH-810DC
MODEL H-809CTM- PORTABLE 12/24 VDC AIR SAMPLER

The Model H-809C is a lightweight GRAB sampler designed for sampling airborne particulates or combination particulates and iodines in the field using a motorized vehicle. The unit is supplied with a battery jumper type cable with large alligator clamps for connecting directly to battery terminals. It may be used with one of the RADeCO precision machined aluminum sample holders, selected filter discs, high quality radioiodine cartridges, and may be calibrated using one of the RADeCO NIST traceable air flow calibrators to give the user a fully qualified air sampling system.

The flow rate capability of the H-809C is dependent upon the pressure drop across the filter media used. Five CFM may be obtained through a 4" diameter filter, while two to three CFM is the upper limit for open face combination filter and charcoal cartridge filter media. High pressure drop filters and cartridges are not recommended for use with this unit. A number of different sample holders are available as accessories.

More Information

MODEL H-809VTM - PORTABLE HIGH VOLUME AIR SAMPLER

The RADeCO Model H-809V is a lightweight, ruggedized grab sampler designed specifically for heavy duty industrial applications for sampling airborne particulates or combination particulates and iodines. The Model H-809V may be used with RADeCO sample holders that house selected filter discs and high quality RADeCO radioiodine cartridges. The unit may be calibrated using one of the RADeCO NIST traceable air flow calibrators to give the user a fully qualified air sampling system.

There are two versions of the 120V and 230V AC H-809 series air samplers. The H-809VI (pictured) has a small, sintered metal exhaust diffuser and is normally used with combination filter and cartridge holders (typical flow range from 1-8 cfm). The H-809VII has a large exhaust diffuser and is normally used with 4" diameter filter holders (typical flow range from 1-30 cfm).

Standard features of the H-809 series include a spring-loaded face guard, which protects the switch, fuse and flow adjust knob; top mounted eye bolt and carrying strap; and a plastic-coated metal cord clamp that prevents internal damage caused by excess tension on the power cord. The industry standard for high volume air sampling.

More Information

MODEL H-810TM -  HIGH VOLUME AIR SAMPLER WITH AIR VOLUME TOTALIZER

The Model H-810 is a dependable, lightweight RADeCO Grab sampler which incorporates the reliability of the Model H-809V with an Air Volume Totalizer, the new way to measure the volume of air sampled. This microprocessor based unit is designed to eliminate the use of rotameters and mechanical time meters, simplifying air sampling procedures while adding significantly higher accuracy to air sampling data. The Air Volume Totalizer portion of the sampler is composed of an enclosed air-turbine which rotates at speeds proportional to the air velocity of the sampled air. The turbine's rotation is sensed by a reflective sensor/breaker disk. The microprocessor converts the signal to volume and displays the FLOW RATE, TOTAL VOLUME and ELAPSED TIME on the LCD readout.

The Model H-810 may be operated in the TOTAL VOLUME mode or the TOTAL ELAPSED TIME mode with the mode of operation predetermined by the user's established procedures. All functions are entered during the calibration mode. The functions/parameters that are established during calibration may be locked in using the keypad security. When the keypad security is on, all keys on the keypad are disabled, with the exception of the START/STOP and UNITS keys. The UNITS key will toggle the LCD display from CFM to LPM.

More Information

Air Sampling Filter Holders

RADeCO has available the finest line of precision machined, all aluminum, holders for air sampling media. There are four different types of holders:

(1.) Open Face Filter Holder, (2.) Inline Filter Holder, (3.) Open Face Combination Filter and Cartridge Holder, and (4.) Inline Combination Filter and Cartridge Holder. All four types are available for the RADeCO 809, 810,series of air samplers.

RADeCO pioneered the unique two 0-ring method of preventing the sampling air from bypassing the cartridge in the combination holder. This method of sealing the cartridge in the lower body eliminated gasket creep and wrinkling which caused leakage past the cartridge. All 47 mm, 2 inch and 4 inch holders are hard anodized to give the sample holders good chemical resistance to prevent oxidation and to color code the various parts. The main body of each holder is colored blue, while the filter retainer nuts and the cartridge retainers are colored gold for 47 mm, black for 2 inch, and blue for 4 inch.

When ordering, please specify the type of holder desired, the diameter of the filter to be used, and in the case of a combination holder, the type of charcoal or silver zeolite cartridge (RADeCO or Scoff) to be used in the holder.

More Information

The RADeCO Model GY-130

The Radioiodine Sampler is a special cartridge specifically designed for the sampling of airborne concentrations of radioiodine and other gaseous iodine compounds in the presence of radioactive noble gases. Testing indicates that a minimum of radioactive Xenon, Krypton, and other noble gases are retained by the Silver Zeolite thereby minimizing their interference with the radioiodine measurement.


Each batch of Silver Zeolite is thoroughly tested prior to cartridge manufacture assuring a high percentage of radioiodine capture. A certificate is supplied with each order of cartridges certifying the percent retention of radioiodines versus airflow rate through the cartridge.
Routinely, these cartridges are used in-line and downstream of a high efficiency filter which will remove radioactive particulates which can interfere with the radioiodine measurement. Filter papers and combination pre-filter and cartridge sample holders are available as RADeCO accessories.
CAUTION: The Model GY-130 Radioiodine Sampler must not be used in personal respirators for breathing protection

More Information

FILTER PAPERS
HD-2061 This filter paper combines good aerosol filtration efficiency with slightly higher porosity than HD-2024. It is suggested for use as a pre-filter of high volume filter for aerosol filtration. It is composed of micrograms borosilicate fiber resin binder.

LB-5211 Laminated glass filter paper. These products are high efficiency multi-purpose filter materials with good heat resistance. They are particularly recommended for both gas and liquid filtration in the medical field and for air monitoring applications. The base material consists of micrograms borosilicate fibers with low amounts of acrylic resin, the composition of which corresponds to the description listed in DFR Title 21, Part 177.2260, Filter, Resin Bonded.
 
Air Flow Calibrator

bullet

Rugged Construction

bullet

Direct Reading in CFM or LPM

bullet

Reflective ARC for Parallax Correction

bullet

Better than 5% Accuracy of Reading

bullet

Three Flow Ranges

bullet

Certified and Traceable to NIST

RADeCO's Air Flow Calibrators are the most durable and repeatable
calibration devices available. RADeCO Calibrators are constructed of a
precision machined aluminum venturi tub and an appropriately ranged
magnahelic gauge moutned in a rugged steel case. Our Air Flow
Calibrators are simple, cost-effective and consistently accurate, year after
year.

More Information

12/24 Battery Pack - EXCELLENT TOOL FOR EMERGENCY RESPONSE OR ROUTINE SAMPLING
 

bulletEnough power to sample for a variety of situations
bulletHeavy duty cable and slip connector or jumper cable clamps
bulletPowered by two 12 volt sealed, lead-acid batteries
bullet12 volt systems use the batteries in parallel, 24 volt systems in series
bulletDC outlet powers a variety of 12 volt accessories
bulletWeighs 36 lbs. 16” H x 7”D x 12” W
bulletRecharge from any 120 volt AC or 12V DC power supply; 12 volt charger is included
 

More Information

LAURUS Systems, Inc.               Phone:  410-465-5558

8779 Autumn Hill Drive                   Fax:       410-465-5257

Ellicott City, MD 21043

email:  LauraLynch@LaurusSystems.com                

Copyright (c) 2001 LAURUS Systems, Inc.

Add Me!
 
FastCounter by bCentral

alarming dosimeter, dosimeter, dosimeters, Electronic dosimeter, electronic alarming dosimeter, keV, meV, Chirper, EPD, Dose, dose rate, Beta, Gamma, X-ray, Survey Meter, RAD-60, Emergency, Emergency Management, HAZMAT, RADOS, Electronic Dosimetry, Dosimeter, Electronic, Alarming, Radiation Detector, Emergency response, first responder, transportation, dosimeter, dosimeter, Radiation Detection, Contamination Monitor, DIS, DIS-100, PDU-1, Direct Ion Chamber, Ion, Neutron, Access Control, Waste Management, Decommissioning, Software, Reader, Readers, Dose Control, Dose of Record, RWP, TLD, Thermoluminescent Dosimetry, AAM, Area Monitoring, Neutron, Gamma, Beta Radiation, Alpha Radiation, Personnel Monitoring, Air Monitor, Nuclear Power Plant, Personnel Dose, Body Monitor, nuclear Medicine, nuclear, medical physics, health physics, dose tracking ADR, ELD, RAD, RADSAFE, transdose, telemetry, remote monitor, remote monitoring, Government purchase card, credit cards, Rad-51, Rad-50, Rad-52, ADR-1, Programmable Dosimeter, Siemens, MG, SAIC, Bicron, Indus, Survey system, IVTS, Site-Wise, MJW Software, VSDS, ACS, Access Control Systems, Visual Survey Mapping, GEDDS, Electronic Remote Monitoring Software, Military DIS, Military, Radiation Protection, Radiation Detector, Public Health, Homeland Security, Personnel Security, Customs, Custom Agent, Siemens, RADOS, MGP, SAIC, Radiation, Dosimeter, Alarming Dosimeter, Silicon Diode Detector, Pulse, Cyclotron, Reactor, ALARA, 10-CFR, Meets NRC Standard, NRC, NREP, CRCPD, Electronic Dosimeter, Electronic Alarming Dosimeter, Alarm settings, RAD-51, RAD-60, x-ray, Gamma, BETA, Neutron, Critical incident, emergency, Online shopping, Order Dosimeters Online